Short Description:

RP6-63S is a critical component of any emergency or standby power system. When the normal(preferred) source of power is lost, it will quickly and safely shift the load circuit from the normal source of power to the emergency (Reserve) source of power.


Product Detail

Model and meaning

 

RP6-63S is a critical component of any emergency or standby power system. When the normal(preferred) source of power is lost, it will quickly and safely shift the load circuit from the normal source of power to the emergency (Reserve) source of power. This permits critical loads to continue running with minimal or no outage. After the normal source of power has been restored, the re-transfer process returns the load circuit to the normal power source

1) The setting is formed with two sets power-operated operation mechanism circuit breakers and mechanical interlocking, fuse, wiring terminal.

2) Two-set circuit breakers have electric interlocking and mechanical interlocking double

protections to prevent the two-set circuit breaker close at the same time.

3) The setting suits for power grid with AC 50/60HZ ,control voltage 220VAC and rated current up to 63A, control the power pass the case, frame board control push button (user self-prepared and connect to) direct control two sets power operated operation mechanism to carry out the power reliable changeover.

4) Suitable for general manual work control occasion, simple structure, low cost

 

Normal working conditions

◆ Ambient temperature: -5~+40℃, and average temperature in 24 hours below +35℃ (except for special orders).

◆Elevation of installation site: 2000m

◆Relative humidity: not exceeding 50% at the maximum ambient temperature of +40℃.

◆With lower temperature, higher humidity would be permitted, but the lowest average

temperature in a month not exceeding 90% in that month, and giving consideration to the

dews on the goods surface, which would appear due to temperature change.

◆Pollution protection: 3 grade

◆The breaker should be put in the place where there isn't any explosive medium and conductive dust and no gas, which would corrode metal or destroy the insulation.

 

Technical Index

Rated Current Ie

6A,10A,16A,20A,25A,32A,40A,50A,63A

Electrical Appliances Class

CB

Use Category

AC-33iB

Tripping Current

5-10In( type C)  10-15In( type D)

Rated Control Voltage

220V(240V)     Note:120V need to customize

Rated Voltage Ue

220V(2P)       400V(3P,4P)

Rated Frequency

50/60Hz

Rated Short Circuit Connecting Ability Icm

7.65KA

Rated Short Circuit Breaking Ability Icn(effective value)

5KA


Installation Dimension